Equipment


Cliquer sur Français pour lire la version française de ce document. Français

This page contains the following sections:
  • Reactors
    • Semi-industrial-scale 3-phase plasma reactor for nanoparticles synthesis: 1 kg/h
    • Laboratory-scale reactor for nanoparticle synthesis: 500 W – 10 g/h
    • Reforming bench : 1 kWe / 10 kWth
    • High pressure discharge microreactor: 200 bars - 500 W
  • Power supplies
    • 260 kW : 700 V / 400 A / 60-600 Hz (Three-phase)
    • 10 kW : 15 kV / 660 mA DC Resonace converter-based TECHNIX
    • 7 kW : 6 kV / 1 A DC Chopper-based CIRTEM
    • 5 kW : 10 kV /500 mA (AC / DC) (HT transformer)
  • Diagnostic and analysis
    • Bichromatic optical pyrometer IRCON MODLINE 3
    • Optical spectrometer HORIBA Jobin Yvon FHR 640
    • Digital video camera recorder DM – MV500
    • Spectrophotometer UV/Vis Philips PU 8730
    • Gas analysis bench ROSEMOUNT NGA 2000 (including 2 NDIR, 1 TCD) (on-line analysisH2, CO, CO2, CH4)
    • Gas phase chromatograph HP 5890 series II
    • Gas phase chromatograph Perichrome
    • Precision Power Analyzer Voltech PM3000
    • Digital oscilloscope HP54615
    • HT and current probes
  • Others
    • Gas bottles store
    • Helium recycling (200 Nm3/h)
    • Ventilation
    • Process water recycling
    • Nanoparticles feeders and filters (1 kg/h)

1. Reactors

Three-phase plasma reactor Three-phase plasma reactor
  • Semi-industrial-scale 3-phase plasma reactor for nanoparticles synthesis

    • Electrodes: Graphite (3)
    • Maximum current intensity (rms): 400 A
    • Maximum electric power: 260 kW
    • Current frequency: 50 - 660 Hz
    • Plasma gas: nitrogen, helium, argon, hydrogen, carbon monoxide,... Max. gas flow rate 12 m3/h
    • Carbon feedstock: Solids, liquids or gasese. Max. flow rate 5 kg/h
    • Pressure: Atmospheric
    • Metrology and diagnostic : Heat balance, pyrometry, optical emission spectroscopy, gas analysis
  • Laboratory-scale reactor for nanoparticle synthesis: 500 W – 10 g/h

  • Reforming bench : 1 kWe / 10 kWth

  • High pressure discharge microreactor: 200 bars - 500 W

[retour]

2. Power supplies

Source électrique triphasé Three-phase power supply
  • 260 kW : 700 V / 400 A / 60-600 Hz (Three-phase)
DC Resonace converter-based TECHNIX DC Resonace converter-based TECHNIX
  • 10 kW: 15 kV / 660 mA DC Resonace converter-based TECHNIX
DC Chopper-based CIRTEM DC Chopper-based CIRTEM
  • 7 kW: 6 kV / 1 A DC Chopper-based CIRTEM
HT transformer HT transformer
  • 5 kW: 10 kV / 500 mA (AC / DC) (HT transformer)
[retour]

3. Diagnostics and analysis

  • Bichromatic optical pyrometer IRCON MODLINE 3
  • Optical spectrometer HORIBA Jobin Yvon FHR 640
  • Digital video camera recorder DM – MV500
  • Spectrophotometer UV/Vis Philips PU 8730
  • Gas analysis bench ROSEMOUNT NGA 2000 (including 2 NDIR, 1 TCD) (on-line analysisH2, CO, CO2, CH4)
  • Gas phase chromatograph HP 5890 series II
  • Gas phase chromatograph Perichrome
  • Precision Power Analyzer Voltech PM3000
  • Digital oscilloscope HP54615
  • HT and current probes
[retour]

4. Others

  • Gas bottles store
  • Helium recycling (200 Nm3/h)
  • Ventilation
  • Process water recycling
  • Nanoparticles feeders and filters (1 kg/h)
[retour]

Click on Members for visiting this topic. Modelling Click on Projects for visiting this topic. Research Projects Click on Members for visiting this topic. Members Click on Publications for visiting this topic. Publications
Click on Plasma conversion processes for visiting this topic. Plasma Conversion Processes
 


[ About... | Diary | Research Teams | Projects | Recruitment | Softwares | Teaching and Training ]
Centre Energétique et Procédés Ecole des Mines de Paris - BP 207 F-06904 Sophia Antipolis Cedex France
Email : webmaster@scep.ensmp.fr - Tél: +33 (0)4 93 95 75 75 - Fax: +33 (0)4 93 95 75 35
Powered by Zope, CPS and Nuxeo