Français
This page contains the following sections:
- Reactors
- Semi-industrial-scale 3-phase plasma reactor for
nanoparticles synthesis: 1 kg/h
- Laboratory-scale reactor for nanoparticle synthesis:
500 W – 10 g/h
- Reforming bench : 1 kWe / 10 kWth
- High pressure discharge microreactor:
200 bars - 500 W
- Power supplies
- 260 kW : 700 V / 400 A / 60-600 Hz (Three-phase)
- 10 kW : 15 kV / 660 mA DC Resonace converter-based
TECHNIX
- 7 kW : 6 kV / 1 A DC Chopper-based CIRTEM
- 5 kW : 10 kV /500 mA (AC / DC) (HT transformer)
- Diagnostic and analysis
- Bichromatic optical pyrometer IRCON MODLINE 3
- Optical spectrometer HORIBA Jobin Yvon FHR 640
- Digital video camera recorder DM – MV500
- Spectrophotometer UV/Vis Philips PU 8730
- Gas analysis bench ROSEMOUNT NGA 2000 (including 2 NDIR,
1 TCD) (on-line analysisH2, CO,
CO2, CH4)
- Gas phase chromatograph HP 5890 series II
- Gas phase chromatograph Perichrome
- Precision Power Analyzer Voltech PM3000
- Digital oscilloscope HP54615
- HT and current probes
- Others
- Gas bottles store
- Helium recycling (200 Nm3/h)
- Ventilation
- Process water recycling
- Nanoparticles feeders and filters (1 kg/h)
1. Reactors
Three-phase plasma reactor
|
Semi-industrial-scale 3-phase plasma reactor for
nanoparticles synthesis
- Electrodes: Graphite (3)
- Maximum current intensity (rms): 400 A
- Maximum electric power: 260 kW
- Current frequency: 50 - 660 Hz
- Plasma gas: nitrogen, helium, argon, hydrogen,
carbon monoxide,... Max. gas flow rate 12
m3/h
- Carbon feedstock: Solids, liquids or gasese. Max.
flow rate 5 kg/h
- Pressure: Atmospheric
- Metrology and diagnostic : Heat balance, pyrometry,
optical emission spectroscopy, gas analysis
|
Laboratory-scale reactor for nanoparticle
synthesis: 500 W – 10 g/h
Reforming bench : 1 kWe / 10 kWth
High pressure discharge microreactor:
200 bars - 500 W
[retour]
2. Power supplies
Three-phase power supply
|
- 260 kW : 700 V / 400 A / 60-600 Hz (Three-phase)
|
DC Resonace converter-based
TECHNIX
|
- 10 kW: 15 kV / 660 mA DC Resonace converter-based
TECHNIX
|
DC Chopper-based CIRTEM
|
- 7 kW: 6 kV / 1 A DC Chopper-based CIRTEM
|
HT transformer
|
- 5 kW: 10 kV / 500 mA (AC / DC) (HT transformer)
|
[retour]
3. Diagnostics and analysis
- Bichromatic optical pyrometer IRCON MODLINE 3
- Optical spectrometer HORIBA Jobin Yvon FHR 640
- Digital video camera recorder DM – MV500
- Spectrophotometer UV/Vis Philips PU 8730
- Gas analysis bench ROSEMOUNT NGA 2000 (including 2 NDIR,
1 TCD) (on-line analysisH2, CO,
CO2, CH4)
- Gas phase chromatograph HP 5890 series II
- Gas phase chromatograph Perichrome
- Precision Power Analyzer Voltech PM3000
- Digital oscilloscope HP54615
- HT and current probes
[retour]
4. Others
- Gas bottles store
- Helium recycling (200 Nm3/h)
- Ventilation
- Process water recycling
- Nanoparticles feeders and filters (1 kg/h)
[retour]
Plasma Conversion Processes
|